Profiling FAQ #3: How do -exclude and -include on vsinstr differ from -start / -suspend / -resume, etc.
VSinstr has two different categories of switches. The first category of switches control which methods get instrumented. The second category of switches control whether or not profiling collection is enabled or not. They are completely orthogonal.
Collection control: Richard gives details of the profiler collection routines at the API level here. However, you can also use VSInstr to control when we are actively collecting data.
Here's the relevant stuff from VSInstr /?
/START:inside|outside,funcname
Start/Stop pair inserted at location in funcname
/SUSPEND:inside|outside,funcname
Suspend/Resume pair inserted at location in funcname
/STARTONLY:before|after|top|bottom,funcname
Start inserted at location in funcname
/STOPONLY:before|after|top|bottom,funcname
Stop inserted at location in funcname
/SUSPENDONLY:before|after|top|bottom,funcname
Suspend inserted at location in funcname
/RESUMEONLY:before|after|top|bottom,funcname
Resume inserted at location in funcname
/MARK:before|after|top|bottom,funcname,markid
Mark inserted at location in funcname with markid
Instrumentation Control: These switches determine which functions get probes inserted in them. I give a little bit of background on what the probes are in this post.
/EXCLUDE:funcspec[;funcspec]+
Everything but funcname will be instrumented
/INCLUDE:funcspec[;funcspec]+
only funcname will be instrumented
Using them together: The reason we have these two separate categories is so that you can specify that you want to instrument only certain functions and you are only interested in collecting during certain phases of execution. Another way of putting this is that Instrumentation Control determines WHICH data you can collect and Collection Control determines WHEN you collect it.
Why should I care about these switches?: In a word, overhead. Every probe inserted modifies the behavior of the original program slightly. We do subtract out an appoximation of this overhead at analysis time, but they still have subtle timing effects on multithreaded apps. Also, as Richard says in his post that I linked to above, collection and instrumentation control really help control the potentially massive volume of data collected during a trace run.
Comments
- Anonymous
June 09, 2005
I’ve pulled together all of the technical articles and walkthroughs from the various team member blogs...