Update Defender for IoT OT monitoring software
This article describes how to update Defender for IoT software versions on OT sensor and legacy on-premises management console appliances.
You can purchase pre-configured appliances for your sensors and legacy on-premises management consoles, or install software on your own hardware machines. In either case, you'll need to update software versions to use new features for OT sensors and on-premises management consoles.
For more information, see Which appliances do I need?, Pre-configured physical appliances for OT monitoring, and OT monitoring software release notes.
Note
Update files are available for currently supported versions only. If you have OT network sensors with legacy software versions that are no longer supported, open a support ticket to access the relevant files for your update.
To perform the procedures described in this article, make sure that you have:
A list of the OT sensors you'll want to update, and the update methods you want to use. Each sensor that you want to update must be both onboarded to Defender for IoT and activated.
Update scenario Method details On-premises management console If the OT sensors you want to update are connected to an on-premises management console, plan to update your on-premises management console before updating your sensors. Cloud-connected sensors Cloud connected sensors can be updated remotely, directly from the Azure portal, or manually using a downloaded update package.
Remote updates require that your OT sensor has version 22.2.3 or later already installed.Locally managed sensors Locally managed sensors can be updated using a downloaded update package, either via a connected on-premises management console, or directly on an OT sensor console. Required access permissions:
To download update packages or push updates from the Azure portal, you need access to the Azure portal as a Security Admin, Contributor, or Owner user.
To run updates on an OT sensor or on-premises management console, you need access as an Admin user.
To update an OT sensor via CLI, you need access to the sensor as a privileged user.
For more information, see Azure user roles and permissions for Defender for IoT and On-premises users and roles for OT monitoring with Defender for IoT.
Important
We recommend verifying that you have sensor backups running regularly, and especially before updating sensor software.
For more information, see Back up and restore OT network sensors from the sensor console.
Make sure that your sensors can reach the Azure data center address ranges and set up any extra resources required for the connectivity method your organization is using.
For more information, see OT sensor cloud connection methods and Connect your OT sensors to the cloud.
Make sure that your firewall rules are configured as needed for the new version you're updating to.
For example, the new version might require a new or modified firewall rule to support sensor access to the Azure portal. From the Sites and sensors page, select More actions > Download sensor endpoint details for the full list of endpoints required to access the Azure portal.
For more information, see Networking requirements and Sensor management options from the Azure portal.
This section describes how to update Defender for IoT OT sensors using any of the supported methods.
Sending or downloading an update package and running the update are two separate steps. Each step can be done one right after the other or at different times.
For example, you might want to first send the update to your sensor or download an update package, and then have an administrator run the update later on, during a planned maintenance window.
If you're using a legacy on-premises management console, make sure that you update the on-premises management console before updating any connected sensors.
On-premises management software is backwards compatible, and can connect to sensors with earlier versions installed, but not later versions. If you update your sensor software before updating your on-premises management console, the updated sensor will be disconnected from the on-premises management console.
Select the update method you want to use:
This procedure describes how to send a software version update to OT sensors at one or more sites, and run the updates remotely using the Azure portal. We recommend that you update the sensor by selecting sites and not individual sensors.
In Defender for IoT in the Azure portal, select Sites and sensors.
If you know your site and sensor name, you can browse or search for it directly, or apply a filter to help locate the site you need.
Select one or more sites to update, and then select Sensor update > Remote update > Step one: Send package to sensor.
For one or more individual sensors, select Step one: Send package to sensor. This option is also available from the ... options menu to the right of the sensor row.
In the Send package pane that appears, under Available versions, select the software version from the list. If the version you need doesn't appear, select Show more to list all available versions.
To jump to the release notes for the new version, select Learn more at the top of the pane.
The lower half of the page shows the sensors you selected and their status. Verify the status of the sensors. A sensor might not be available for update for various reasons, for example, the sensor is already updated to the version you want to send, or there's a problem with the sensor, such as it's disconnected.
Once you've checked the list of sensors to be updated, select Send package, and the software transfer to your sensor machine is started. You can see the transfer progress in the Sensor version column, with the percentage completed automatically updating in the progress bar, so you can see that the process has started and letting you track its progress until the transfer is complete. For example:
When the transfer is complete, the Sensor version column changes to Ready to update.
Hover over the Sensor version value to see the source and target version for your update.
To install the sensor software update, ensure that you see the Ready to update icon in the Sensor version column.
Select one or more sites to update, and then select Sensor update > Remote update > Step 2: Update sensor from the toolbar. The Update sensor pane opens in the right side of the screen.
For an individual sensor, the Step 2: Update sensor option is also available from the ... options menu.
In the Update sensor pane that appears, verify your update details.
When you're ready, select Update now > Confirm update to install the update on the sensor. In the grid, the Sensor version value changes to Installing, and an update progress bar appears showing you the percentage complete. The bar automatically updates, so that you can track the progress until the installation is complete.
When completed, the sensor value switches to the newly installed sensor version number.
If a sensor update fails to install for any reason, the software reverts back to the previous version installed, and a sensor health alert is triggered. For more information, see Understand sensor health and Sensor health message reference.
To confirm that the update process completed successfully, check the sensor version in the following locations for the new version number:
In the Azure portal, on the Sites and sensors page, in the Sensor version column
On the OT sensor console:
- In the title bar
- On the Overview page > General Settings area
- In the System settings > Sensor management > Software update pane
On a connected on-premises management console, on the Site Management page
Upgrade log files are located on the OT sensor machine at /opt/sensor/logs/legacy-upgrade.log
, and are accessible to the cyberx_host user via SSH.
This procedure describes how to update on-premises management console software. You might need these steps before updating OT sensors remotely from the Azure portal or as a standalone update process.
Updating an on-premises management console takes about 30 minutes.
Important
If you're updating the on-premises management console as part of an OT sensor process, you must update your on-premises management console before updating your OT sensors.
The software version on your on-premises management console must be equal to or greater than that of your most up-to-date sensor version. Each on-premises management console version is backwards compatible to older, supported sensor versions, but cannot connect to newer sensor versions.
This procedure describes how to download an update package for a standalone update. If you're updating your on-premises management console together with connected sensors, we recommend using the Update sensors (Preview) menu from on the Sites and sensors page instead.
In Defender for IoT on the Azure portal, select Getting started > On-premises management console.
In the On-premises management console area, select the download scenario that best describes your update, and then select Download.
The update package is downloaded with a file syntax name of
management-secured-patcher-<version number>.tar
, where<version number>
is the software version number you're updating to.
All files downloaded from the Azure portal are signed by root of trust so that your machines use signed assets only.
Sign into your on-premises management console and select System Settings > Version Update.
In the Upload File dialog, select BROWSE FILE and then browse to and select the update file you'd downloaded from the Azure portal.
The update process starts, and may take about 30 minutes. During your upgrade, the system is rebooted twice.
Sign in when prompted and check the version number listed in the bottom-left corner to confirm that the new version is listed.
For more information, see: