CIM_ElementSettingData class
Represents an association between a managed element and its associated setting data. This association also describes whether this is a default or current setting.
The following syntax is simplified from MOF code and includes all inherited properties.
Syntax
[Association, Abstract, Version("2.19.1"), UMLPackagePath("CIM::Core::Settings"), AMENDMENT]
class CIM_ElementSettingData
{
CIM_ManagedElement REF ManagedElement;
CIM_SettingData REF SettingData;
uint16 IsDefault;
uint16 IsCurrent;
uint16 IsNext;
};
Members
The CIM_ElementSettingData class has these types of members:
Properties
The CIM_ElementSettingData class has these properties.
-
IsCurrent
-
-
Data type: uint16
-
Access type: Read-only
Indicates whether the referenced setting is currently being used by the element.
-
-
Unknown (0)
-
Is Current (1)
-
Is Not Current (2)
IsDefault
-
Data type: uint16
-
Access type: Read-only
Indicating whether the setting is a default setting for the element.
Unknown (0)
Is Default (1)
Is Not Default (2)
IsNext
-
Data type: uint16
-
Access type: Read-only
A flag that indicates when and how often to apply the setting.
For example, the setting could be applied on a re-initialization, reset, reconfiguration request. This could be a permanent setting, or a setting used only one time, as indicated by the flag. If it is a permanent setting then the setting is applied every time the managed element reinitializes, until this flag is manually reset. However, if it is single use, then the flag is automatically cleared after the settings are applied. In addition, if this flag is set to value other than 0 (Unknown), then this takes precedence over a SettingData property that is set to "Default".
If the managed element is a computer system, and the value of this flag is "Is Next", then the setting will be effective next time the system resets. And, unless this flag is changed, it will persist for subsequent system resets. However, if this flag is set to "Is Next For Single Use", then this setting will only be used once and the flag would be reset after that to 2 (Is Not Next). So, in the above example, if the system reboots in a quick succession, the setting will not be used at the second reboot.
Unknown (0)
Unknown.
Is Next (1)
The setting will be applied to the managed element every time the managed element is reset.
Is Not Next (2)
This setting is no longer used.
Is Next For Single Use (3)
The setting will only be applied to the managed element once, and then this flag will be set to Is Not Next (2).
ManagedElement
-
Data type: CIM_ManagedElement
-
Access type: Read-only
The managed element.
SettingData
-
Data type: CIM_SettingData
-
Access type: Read-only
-
Qualifiers: Key
The setting data associated with the element.
Requirements
Minimum supported client |
None supported |
Minimum supported server |
Windows Server 2016 |
Namespace |
Root\HyperVCluster\v2 |
MOF |
|
DLL |
|