Msvm_SyntheticEthernetPort class
Represents a synthetic Ethernet adapter. This adapter is the preferred network adapter because of its performance and hot configurability.
The following syntax is simplified Managed Object Format (MOF) code, and it includes all of the inherited properties.
Syntax
[Dynamic, Provider("VmmsWmiInstanceAndMethodProvider"), AMENDMENT]
class Msvm_SyntheticEthernetPort : CIM_EthernetPort
{
string Caption = "Ethernet Port";
string Description = "Microsoft Synthetic Ethernet Port";
string ElementName = "Network Adapter";
datetime InstallDate;
string Name = "Ethernet Port";
uint16 OperationalStatus[] = 2;
string Status;
uint16 HealthState = 5;
uint16 EnabledState = 5;
string OtherEnabledState;
uint16 RequestedState = 12;
datetime TimeOfLastStateChange;
string SystemCreationClassName = "Msvm_ComputerSystem";
string SystemName;
boolean PowerManagementSupported;
uint16 PowerManagementCapabilities[];
uint16 Availability;
uint16 StatusInfo;
uint32 LastErrorCode;
string ErrorDescription;
boolean ErrorCleared;
uint64 PowerOnHours;
uint64 TotalPowerOnHours;
string IdentifyingDescriptions[];
uint16 AdditionalAvailability[] = 6;
uint64 MaxQuiesceTime;
uint64 MaxSpeed = 1000000000;
uint64 RequestedSpeed = 1000000000;
string OtherNetworkPortType;
uint16 PortNumber = 0;
string OtherLinkTechnology;
string PermanentAddress;
boolean FullDuplex = True;
boolean AutoSense = True;
uint64 SupportedMaximumTransmissionUnit = 1500;
string NetworkAddresses[];
string CapabilityDescriptions[];
uint16 EnabledCapabilities[];
string OtherEnabledCapabilities[];
string StatusDescriptions[] = "OK";
uint16 EnabledDefault = 2;
string CreationClassName = "Msvm_SyntheticEthernetPort";
string DeviceID = "Microsoft:GUID";
string OtherIdentifyingInfo[];
uint16 LocationIndicator = 4;
uint16 UsageRestriction = 4;
string OtherPortType = "Virtual Ethernet";
uint64 Speed = 1000000000;
uint16 LinkTechnology = 2;
uint64 ActiveMaximumTransmissionUnit = 1500;
uint16 PortType = 1;
uint32 MaxDataSize = 1500;
uint16 Capabilities[];
};
Members
The Msvm_SyntheticEthernetPort class has these types of members:
Methods
The Msvm_SyntheticEthernetPort class has these methods.
Method | Description |
---|---|
EnableDevice | This method is not supported. |
OnlineDevice | This method is not supported. |
QuiesceDevice | This method is not supported. |
RequestStateChange | This method is not supported. |
Reset | This method is not supported. |
RestoreProperties | This method is not supported. |
SaveProperties | This method is not supported. |
SetPowerState | This method is not supported. |
Properties
The Msvm_SyntheticEthernetPort class has these properties.
-
ActiveMaximumTransmissionUnit
-
-
Data type: uint64
-
Access type: Read-only
-
Qualifiers: Units ("Bytes")
The active or negotiated maximum transmission unit (MTU) that can be supported. This property is inherited from CIM_NetworkPort and is always set to 1500.
-
-
AdditionalAvailability
-
-
Data type: uint16 array
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_LogicalDevice.Availability")
Additional availability and status of the device, beyond that specified in the Availability property. This property is inherited from CIM_LogicalDevice and is always set to 6 (Not Applicable).
-
-
AutoSense
-
-
Data type: boolean
-
Access type: Read-only
Indicates whether the network port is capable of automatically determining the speed or other communications characteristics of the attached network media. This property is inherited from CIM_NetworkPort and is always set to True.
-
-
Availability
-
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_AssociatedPowerManagementService.PowerState", "CIM_ManagedSystemElement.OperationalStatus", "CIM_EnabledLogicalElement.EnabledState"), MappingStrings ("MIF.DMTF|Operational State|006.5", "MIB.IETF|HOST-RESOURCES-MIB.hrDeviceStatus", "MIF.DMTF|Host Device|001.5"), ModelCorrespondence ("CIM_LogicalDevice.AdditionalAvailability")
The primary availability and status of the device. This property is inherited from CIM_LogicalDevice and is always set to 6 (Not Applicable).
-
-
Capabilities
-
-
Data type: uint16 array
-
Access type: Read-only
-
Qualifiers: ArrayType ("Indexed"), ModelCorrespondence ("CIM_EthernetPort.CapabilityDescriptions")
The capabilities of the Ethernet port. For example, the device might support AlertOnLan, WakeOnLan, Load Balancing, or FailOver. If failover or load balancing capabilities are listed, a SpareGroup (failover) or ExtraCapacityGroup (load balancing) should also be defined to completely describe the capability. This property is inherited from CIM_EthernetPort and is not used.
-
-
Unknown (0)
-
Other (1)
-
AlertOnLan (2)
-
WakeOnLan (3)
-
FailOver (4)
-
LoadBalancing (5)
CapabilityDescriptions
-
Data type: string array
-
Access type: Read-only
-
Qualifiers: ArrayType ("Indexed"), ModelCorrespondence ("CIM_EthernetPort.Capabilities")
An array of free-form strings that provides more detailed explanations for any of the EthernetPort features that are indicated in the Capabilities property array. Note, each entry of this array is related to the entry in the Capabilities property array that is located at the same index. This property is inherited from CIM_EthernetPort and is not used.
Caption
-
Data type: string
-
Access type: Read-only
-
Qualifiers: MaxLen (64)
A short textual description (one- line string) of the object. This property is inherited from CIM_ManagedElement and is always set to "Ethernet Port".
CreationClassName
The name of the class or the subclass that is used in the creation of an instance. This property is inherited from CIM_LogicalDevice and is always set to "Msvm_SyntheticEthernetPort".
Description
-
Data type: string
-
Access type: Read-only
A textual description of the object. This property is inherited from CIM_ManagedElement and is always set to "Microsoft Synthetic Ethernet Port".
DeviceID
An address or other identifying information used to uniquely name the logical device. This property is inherited from CIM_LogicalDevice and always uses the format "Microsoft:GUID".
ElementName
-
Data type: string
-
Access type: Read-only
A user-friendly name for the object. This property is inherited from CIM_ManagedElement and is set to "Network Adapter".
EnabledCapabilities
-
Data type: uint16 array
-
Access type: Read-only
-
Qualifiers: ArrayType ("Indexed"), ModelCorrespondence ("CIM_EthernetPort.Capabilities", "CIM_EthernetPort.OtherEnabledCapabilities")
The capabilities that are enabled from the list of all supported ones, which are defined in the Capabilities property array. This property is inherited from CIM_EthernetPort but is not used.
Unknown (0)
Other (1)
AlertOnLan (2)
WakeOnLan (3)
FailOver (4)
LoadBalancing (5)
EnabledDefault
-
Data type: uint16
-
Access type: Read/write
An administrator's default or startup configuration for the enabled state of an element. This property is inherited from CIM_EnabledLogicalElement and is always set to 2 (Enabled).
EnabledState
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.OtherEnabledState")
The enabled and disabled states of this element. This property is inherited from CIM_EnabledLogicalElement and is always set to 5 (Not Applicable).
Not Applicable (5)
Indicates the element does not support to be enabled or disabled.
ErrorCleared
-
Data type: boolean
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_ManagedSystemElement.OperationalStatus")
This property is inherited from CIM_LogicalDevice but it is not used.
ErrorDescription
-
Data type: string
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_DeviceErrorData.ErrorDescription")
This property is inherited from CIM_LogicalDevice but it is not used.
FullDuplex
-
Data type: boolean
-
Access type: Read-only
Indicates whether the port is operating in full duplex mode. This property is inherited from CIM_NetworkPort and is always set to True.
HealthState
-
Data type: uint16
-
Access type: Read-only
The current health of the element. This property is inherited from CIM_ManagedSystemElement and is always set to 5 (OK).
OK (5)
The element is fully functional and operates within normal operational parameters and without error.
IdentifyingDescriptions
-
Data type: string array
-
Access type: Read-only
-
Qualifiers: ArrayType ("Indexed"), ModelCorrespondence ("CIM_LogicalDevice.OtherIdentifyingInfo")
An array of free-form strings that provide explanations and details behind the entries in the OtherIdentifyingInfo array. This property is inherited from CIM_LogicalDevice and is not used.
InstallDate
-
Data type: datetime
-
Access type: Read-only
-
Qualifiers: MappingStrings ("MIF.DMTF|ComponentID|001.5")
The date the Ethernet port was added to the virtual machine. This property is inherited from CIM_ManagedSystemElement.
LastErrorCode
-
Data type: uint32
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_DeviceErrorData.LastErrorCode")
This property is inherited from CIM_LogicalDevice but it is not used.
LinkTechnology
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_NetworkPort.OtherLinkTechnology")
An enumeration of the types of links. When set to 1 (Other), the related property OtherLinkTechnology contains a string description of the type of link. This property is inherited from CIM_NetworkPort and is always set to 2 (Ethernet).
LocationIndicator
-
Data type: uint16
-
Access type: Read/write
-
Qualifiers: Experimental, ModelCorrespondence ("CIM_AlarmDevice.AlarmState", "CIM_AlarmDevice.AudioIndicatorIsDisabled", "CIM_AlarmDevice.VisualIndicatorIsDisabled", "CIM_AlarmDevice.MotionIndicatorIsDisabled")
The state of an indicator (for example, LED) that is part of a device. Reading the value gives the current state. Writing the value with 'On'/'Off' turns the indicator on/off, other values may not be written. This property is inherited from CIM_EthernetPort and is always set to 4 (Not Supported).
MaxDataSize
-
Data type: uint32
-
Access type: Read-only
-
Qualifiers: MappingStrings ("MIB.IETF|BRIDGE-MIB.dot1dTpPortMaxInfo")
The maximum size of the INFO (non-MAC) field that will be received or transmitted. This property is inherited from CIM_EthernetPort and is always set to 1500.
MaxQuiesceTime
-
Data type: uint64
-
Access type: Read-only
-
Qualifiers: Deprecated ("No value"), Units ("MilliSeconds")
This property is inherited from CIM_LogicalDevice but it is not used.
MaxSpeed
-
Data type: uint64
-
Access type: Read-only
-
Qualifiers: Units ("Bits per Second")
The maximum bandwidth of the Port in Bits per Second. This property is inherited from CIM_LogicalPort and is always set to 1000000000.
Name
-
Data type: string
-
Access type: Read-only
-
Qualifiers: MaxLen (1024)
A user-friendly name for the object. This property is inherited from CIM_ManagedSystemElement and is always set to "Ethernet Port".
NetworkAddresses
-
Data type: string array
-
Access type: Read-only
Ethernet/802.3 MAC addresses formatted as twelve hexadecimal digits (for example, "010203040506"), with each pair representing one of the six octets of the MAC address in "canonical" bit order (the Group address bit is found in the low order bit of the first character of the string). This property is inherited from CIM_EthernetPort and is not used.
OperationalStatus
-
Data type: uint16 array
-
Access type: Read-only
-
Qualifiers: ArrayType ("Indexed"), ModelCorrespondence ("CIM_ManagedSystemElement.StatusDescriptions")
The current status of the element. This property is inherited from CIM_ManagedSystemElement and is always set to 2 (OK).
OK (2)
Indicates full functionality without errors.
OtherEnabledCapabilities
-
Data type: string array
-
Access type: Read-only
-
Qualifiers: ArrayType ("Indexed"), ModelCorrespondence ("CIM_EthernetPort.EnabledCapabilities")
An array of free-form strings that provides more detailed explanations for any of the enabled capabilities that are specified as "Other". This property is inherited from CIM_EthernetPort and is not used.
OtherEnabledState
-
Data type: string
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.EnabledState")
The enabled or disabled state of the element when the EnabledState property is set to 1 (Other). This property is inherited from CIM_EnabledLogicalElement and is not used.
OtherIdentifyingInfo
-
Data type: string array
-
Access type: Read-only
-
Qualifiers: MaxLen (256), ArrayType ("Indexed"), ModelCorrespondence ("CIM_LogicalDevice.IdentifyingDescriptions")
Any data, in addition to device ID information, that could be used to identify a logical device. This property is inherited from CIM_LogicalDevice and is not used.
OtherLinkTechnology
-
Data type: string
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_NetworkPort.LinkTechnology")
A string value that describes LinkTechnology when it is set to 1 (Other). This property is inherited from CIM_NetworkPort.
OtherNetworkPortType
-
Data type: string
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_NetworkPort.OtherPortType"), ModelCorrespondence ("CIM_LogicalPort.PortType")
This property is inherited from CIM_NetworkPort and is set to NULL.
OtherPortType
-
Data type: string
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_LogicalPort.PortType")
The type of module, when PortType is set to 1 (Other). This property is inherited from CIM_LogicalPort and is always set to "Virtual Ethernet".
PermanentAddress
-
Data type: string
-
Access type: Read-only
-
Qualifiers: MaxLen (64), MappingStrings ("MIF.DMTF|Network Adapter 802 Port|001.2")
The network address that is hardcoded into a port. This 'hardcoded' address can be changed using a firmware upgrade or a software configuration. When this change is made, the field should be updated at the same time. The PermanentAddress property should be left blank if no 'hardcoded' address exists for the NetworkAdapter. This property is inherited from CIM_NetworkPort.
PortNumber
-
Data type: uint16
-
Access type: Read-only
Network ports are often numbered relative to either a logical module or a network element. This value is 1 for emulated NICs, 0 for all others. This property is inherited from CIM_NetworkPort and is always set to 0.
PortType
-
Data type: uint16
-
Access type: Read-only
The specific mode that is currently enabled for the port. When set to 1 (Other), the related property OtherPortType contains a string description of the type of port. This property is inherited from CIM_EthernetPort and is always set to 1 (Other).
PowerManagementCapabilities
-
Data type: uint16 array
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_PowerManagementCapabilities.PowerCapabilities")
This property is inherited from CIM_LogicalDevice but it is not used.
PowerManagementSupported
-
Data type: boolean
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_PowerManagementCapabilities")
This property is inherited from CIM_LogicalDevice but it is not used.
PowerOnHours
-
Data type: uint64
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_PoweredStatisticalData.PowerOnHours"), Units ("Hours"), Counter
This property is inherited from CIM_LogicalDevice but it is not used.
RequestedSpeed
-
Data type: uint64
-
Access type: Read/write
-
Qualifiers: Units ("Bits per Second"), ModelCorrespondence ("CIM_LogicalPort.Speed")
The requested bandwidth of the port, in bits per second. The actual bandwidth is reported in the Speed property. This property is inherited from CIM_LogicalPort and is always set to 1000000000.
RequestedState
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.EnabledState")
The last requested or desired state for the management service. This property is inherited from CIM_EnabledLogicalElement and is always set to 12 (Not Applicable).
Not Applicable (12)
Indicates that this instance does not support the RequestedState property.
Speed
-
Data type: uint64
-
Access type: Read-only
-
Qualifiers: Units ("Bits per Second"), MappingStrings ("MIB.IETF|MIB-II.ifSpeed", "MIF.DMTF|Network Adapter 802 Port|001.5")
The current bandwidth of the port, in bits per second. For ports that vary in bandwidth or for those where no accurate estimation can be made, this property should contain the nominal bandwidth. This property is inherited from CIM_NetworkPort and is always set to 1000000000.
Status
-
Data type: string
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_ManagedSystemElement.OperationalStatus"), MaxLen (10)
This property is inherited from CIM_ManagedSystemElement but it is not used.
StatusDescriptions
-
Data type: string array
-
Access type: Read-only
-
Qualifiers: ArrayType ("Indexed"), ModelCorrespondence ("CIM_ManagedSystemElement.OperationalStatus")
Strings that describe the various OperationalStatus array values. This property is inherited from CIM_ManagedSystemElement and is always set to "OK".
StatusInfo
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_EnabledLogicalElement.EnabledState"), MappingStrings ("MIF.DMTF|Operational State|006.4")
This property is inherited from CIM_LogicalDevice but it is not used.
SupportedMaximumTransmissionUnit
-
Data type: uint64
-
Access type: Read-only
-
Qualifiers: Units ("Bytes")
The maximum transmission unit (MTU) that can be supported. This property is inherited from CIM_NetworkPort and is always set to 1500.
SystemCreationClassName
-
Data type: string
-
Access type: Read-only
-
Qualifiers: Key, Propagated ("CIM_System.CreationClassName"), MaxLen (256)
The creation class name of the scoping system. This property is inherited from CIM_LogicalDevice and is always set to "Msvm_ComputerSystem".
SystemName
-
Data type: string
-
Access type: Read-only
-
Qualifiers: Key, Propagated ("CIM_System.Name"), MaxLen (256)
The NetBIOS name of the hosting computer system. This property will contain the virtual machine ID in GUID form. This property is inherited from CIM_LogicalDevice.
TimeOfLastStateChange
-
Data type: datetime
-
Access type: Read-only
The date or time when the enabled state of the element last changed. This property is inherited from CIM_EnabledLogicalElement and is not used.
TotalPowerOnHours
-
Data type: uint64
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_PoweredStatisticalData.TotalPowerOnHours"), Units ("Hours"), Counter
This property is inherited from CIM_LogicalDevice but it is not used.
UsageRestriction
-
Data type: uint16
-
Access type: Read-only
In some circumstances, a logical port might be identifiable as a front end or back end port. If there is no restriction on the use of the port, then the value should be set to 4 (Not Restricted). This property is inherited from CIM_LogicalPort and is always set to 4 (Not Restricted).
Remarks
Access to the Msvm_SyntheticEthernetPort class might be restricted by UAC Filtering. For more information, see User Account Control and WMI.
Examples
See Querying Networking Objects.
Requirements
Minimum supported client |
None supported |
Minimum supported server |
Windows Server 2008 |
End of client support |
None supported |
End of server support |
Windows Server 2012 R2 |
Namespace |
Root\Virtualization |