The following table shows MIPS error messages number 526 through 610.

No. Severity Message text
526 ERROR Code can only be placed in text
527 ERROR Bad instruction opcode
528 INFO Preparing gp-tables
529 INFO Building gp-tables
530 ERROR Label referenced but not defined: %s
531 ERROR Not all branch-label symbols were defined
532 ERROR C0 opcode must be inside .set noreorder section
533 ERROR Byte address of jump target must fit in 28 bits
534 ERROR Jump target is not word-aligned
536 ERROR Register must differ from base
537 ERROR Operand 1 should be fp reg
538 ERROR ulwu instruction not implemented
539 ERROR coproc doubles not implemented
540 ERROR li.e instruction not implemented
542 ERROR Exponent out of range: %s
543 ERROR Only \\""1\\"" or \\""0\\"" allowed left of binary point: %s
544 ERROR Illegally denormalized fraction: %s
545 ERROR Floating point underflow: %s
546 ERROR -M forbidden when assembler runs on a MIPS machine
547 ERROR -M does not support \\"".extended\\""
548 ERROR -M does not support hex floating point
549 ERROR Floating point literal too long
550 ERROR Too many float literals--compile with \\""-Wb,-nopool\\""
551 ERROR Cannot label a pseudo-op in text section
552 ERROR Shift amount not 0..31
553 ERROR Shift amount not 0..63
554 ERROR gp-relative segments together exceed 64k bytes: %d bytes
558 ERROR MIPS16 move must use a MIPSII gp register
559 ERROR MIPS16 addiu immediate limited to 15 bits
560 ERROR Doubleword opcode not supported by mips2 or earlier
575 ERROR MIPS16 load with symbolic offset must use different base & dest
576 ERROR MIPS16 store may not use symbolic offset in base-offset mode
577 ERROR Non-MIPS16 instruction used in MIPS16 text section
578 ERROR MIPS16 instruction used in non-MIPS16 text section
579 ERROR 2nd register invalid in MIPS16 dsrl and dsra
580 ERROR Branch offset not specified
581 ERROR Relative offset not multiple of 4
582 ERROR Relative offset beyond 32768
583 ERROR cprestore offset must be positive and divisible by 4
584 ERROR .cpalias requires a register argument
585 ERROR Number out of range: %s
586 ERROR MIPS16 general purpose register expected
587 ERROR 2-register MIPS16 jalr must take $ra as first operand
602 ERROR Assembler op/directive expected
603 ERROR Undefined symbol in expression
604 ERROR Invalid symbol in expression: %s
605 ERROR Symbol must have absolute value: %s
607 ERROR No such label
608 ERROR Too many local labels
609 ERROR Overflow
610 WARN Large decimal set sign bit

See Also

MIPS Guide | MIPS Error Messages 1-525 | MIPS Error Messages 611-660 | MIPS Error Messages 661-910 | MIPS Error Messages 911-980

 Last updated on Thursday, April 08, 2004