FwpsPendClassify0 function (fwpsk.h)
A callout's classifyFn function calls FwpsPendClassify0 to pend the current classify request. After the request is pended, the callout driver must complete the processing of the classify request asynchronously by calling FwpsCompleteClassify0.
Syntax
NTSTATUS FwpsPendClassify0(
[in] UINT64 classifyHandle,
[in] UINT64 filterId,
[in] UINT32 flags,
[in, out] FWPS_CLASSIFY_OUT0 *classifyOut
);
Parameters
[in] classifyHandle
The classification handle that identifies the callout driver's processing at the current layer. This handle is obtained by calling FwpsAcquireClassifyHandle0.
[in] filterId
The value of the FilterId member of the classifyFn function's filter parameter. For more information about the FilterId member, see FWPS_FILTER1.
[in] flags
Reserved for future use. Set to zero.
[in, out] classifyOut
Set to the classifyOut parameter of the callout driver's classifyFn function. The classifyOut parameter of classifyFn is listed as an output parameter in the header, but it contains enough information on input to be useful to the engine when passed to FwpsPendClassify.
Return value
The FwpsPendClassify0 function returns one of the following NTSTATUS codes.
Return code | Description |
---|---|
|
The classify request was successfully pended. |
|
The engine does not allow asynchronous classification at the layer from which the call was made. |
|
An error occurred. |
Remarks
FwpsPendClassify0 puts the classification of the indicated event in a pended state. A callout driver typically pends classification so that more processing can be done outside the scope of the classifyFn callout function. The callout driver can then pass the classification handle and any other pertinent data about the indication to a function with less impact on performance than the driver callout functions. When processing is complete, the callout must call FwpsCompleteClassify0 to remove the pended state. At the time of the call to FwpsCompleteClassify, the callout driver must return a filled-out FWPS_CLASSIFY_OUT0 structure just as it would in an inline classification.
FwpsPendClassify0 increments the reference count for the classification handle passed in the classifyHandle parameter. After the callout driver calls this function, it can call FwpsReleaseClassifyHandle0 to release the local instance. When FwpsCompleteClassify0 is called, the reference to the handle will be decremented automatically.
Requirements
Requirement | Value |
---|---|
Minimum supported client | Available starting with Windows 7. |
Target Platform | Universal |
Header | fwpsk.h (include Fwpsk.h) |
Library | Fwpkclnt.lib |
IRQL | <= DISPATCH_LEVEL |