NDISTest 6.5 - [2 Machine] - QosStorageInterop
The DUT must have a QoS-capable CNA adapter and the willing-bit should be turned off. The SUT must have a network adapter capable of working at DUT's line rate. A ISCSI drive should be configured to work over the CNA over either ISCSI connection offered by the CAN or an SMB share should be configured and mounted on drive for testing a NetworkDirect-capable network adapter. No more than one SMB share should be configured on the test machine to ensure no false failures. Test cases are as follows:
Network Traffic ETS Enforcement ensures that CNA does not throttle any network traffic flow when the network traffic class is configured at the traffic rate observed when ETS is disabled.
Storage Traffic ETS Enforcement ensures that CNA does not throttle any storage traffic flow when the storage traffic class is configured at the traffic rate observed when ETS is disabled.
1:1 Network:Storage -- Traffic Distribution of oversubscribed bandwidth ensures that CNA is able to evenly distribute network and storage traffic overload.
2:1 Network:Storage -- Traffic Distribution of oversubscribed bandwidth ensures that CNA is able to prioritize network traffic over storage traffic at a ratio of 2:1.
Test details
Specifications |
|
Platforms |
|
Supported Releases |
|
Expected run time (in minutes) | 10 |
Category | Development |
Timeout (in minutes) | 600 |
Requires reboot | false |
Requires special configuration | false |
Type | automatic |
Additional documentation
Tests in this feature area might have additional documentation, including prerequisites, setup, and troubleshooting information, that can be found in the following topic(s):
Running the test
Before you run the test, complete the test setup as described in the test requirements: LAN Testing Prerequisites.
Troubleshooting
For generic troubleshooting of HLK test failures, see Troubleshooting Windows HLK Test Failures.
For troubleshooting information, see Troubleshooting LAN Testing.
More information
Parameters
Parameter name | Parameter description |
---|---|
queryTestDeviceID | |
SupportDeviceGuid0 | |
ClientMessageDeviceGuid | |
ServerMessageDeviceGuid | |
TestScript | comma separated list of test jobs to run |
ParamStorageDrive | Single Character Drive-letter [mandatory parameter] |
ParamStorageConnectionMode | Storage-connection mode, supported modes are 'ISCSI' and 'ND' [mandatory parameter] |
ParamNetworkTrafficGeneratorThreads | Number of traffic-streams (threads) created by Network traffic generator [optional parameter] |