Requêtes pour la table Pulsations
Pour plus d’informations sur l’utilisation de ces requêtes dans le Portail Azure, consultez le didacticiel Log Analytics. Pour l’API REST, consultez Requête.
Compter les pulsations
Comptez toutes les pulsations d’ordinateurs de la dernière heure.
// Count computers heartbeats in the last hour.
// Normally, agents on VMs generate Heartbeat event every minute.
Heartbeat
| where TimeGenerated > ago(1h)
| summarize count() by Computer
Last heartbeat of each computer (Dernière pulsation de chaque ordinateur)
Affichez la dernière pulsation envoyée par chaque ordinateur.
// Last heartbeat of each computer
// Show the last heartbeat sent by each computer.
Heartbeat
| summarize arg_max(TimeGenerated, *) by Computer
Pics de latence d’ingestion (de bout en bout) - Table de pulsations
Vérifiez les pics de latence dans l’ingestion des pulsations au cours des 24 dernières heures.
// Ingestion latency (end-to-end) spikes - Heartbeat table
// Check for latency spikes in the ingestion of Heartbeats in the last 24 hour.
// This query calculates ingestion duration every 10 minutes, and looks for spikes
let StartTime = ago(24h);
let EndTime = now();
let MinRSquare = 0.9; // Tune the sensitivity of the detection sensor. Higher numbers make the detector more sensitive
Heartbeat
| where TimeGenerated between (StartTime .. EndTime)
// calculate ingestion duration in seconds
| extend IngestionDurationSeconds = (ingestion_time()-TimeGenerated)/1s
// Create a time series
| make-series RatioSeries=avg(IngestionDurationSeconds) default=0 on TimeGenerated in range(StartTime , EndTime,10m)
// Apply a 2-line regression to the time series
| extend (RSquare2, SplitIdx, Variance2, RVariance2, LineFit2) = series_fit_2lines(RatioSeries)
// Find out if our 2-line is trending up or down
|extend (Slope, Interception, RSquare, Variance, RVariance, LineFit) = series_fit_line(LineFit2)
// Check whether the line fit reaches the threshold, and if the spike represents an increase (rather than a decrease)
| project PatternMatch = iff(RSquare2 > MinRSquare and Slope>0, "Spike detected", "No spike")
Pics de latence de l’agent - Table de pulsations
Recherchez les pics de latence de l’agent dans l’ingestion des pulsations au cours des 24 dernières heures.
// Agent latency spikes - Heartbeat table
// Check for agent latency spikes in the ingestion of Heartbeats in the last 24 hour.
// This query calculates ingestion duration every 10 minutes, and looks for spikes
let StartTime = ago(24h);
let EndTime = now();
let MinRSquare = 0.9; // Tune the sensitivity of the detection sensor. Higher numbers make the detector more sensitive
Heartbeat
| where TimeGenerated between (StartTime .. EndTime)
// calculate ingestion duration in seconds
| extend AgentLatencySeconds = (_TimeReceived-TimeGenerated)/1s
// Create a time series
| make-series RatioSeries=avg(AgentLatencySeconds) default=0 on TimeGenerated in range(StartTime , EndTime,10m)
// Apply a 2-line regression to the time series
| extend (RSquare2, SplitIdx, Variance2, RVariance2, LineFit2) = series_fit_2lines(RatioSeries)
// Find out if our 2-line is trending up or down
|extend (Slope, Interception, RSquare, Variance, RVariance, LineFit) = series_fit_line(LineFit2)
// Check whether the line fit reaches the threshold, and if the spike represents an increase (rather than a decrease)
| project PatternMatch = iff(RSquare2 > MinRSquare and Slope>0, "Spike detected", "No spike")
Pulsations récemment arrêtées - Table de pulsations
Répertorie les ressources qui ont cessé d’envoyer des pulsations au cours des 15 dernières minutes.
// Resources, which stopped sending heartbeats in last 15 minutes
Heartbeat
| summarize LastReported=now()-max(TimeGenerated) by ResourceGroup, Resource, ResourceType
// Assuming that heartbeats are sent at least every minute we are looking at 1-15 minute interval
| where LastReported between(1m..15m)
Computers availability today (Disponibilité des ordinateurs aujourd’hui)
Graphiquer le nombre d’ordinateurs envoyant des journaux, chaque heure.
Heartbeat
| summarize dcount(ComputerIP) by bin(TimeGenerated, 1h)
| render timechart
Unavailable computers (Ordinateurs non disponibles)
Répertoriez tous les ordinateurs connus qui n’ont pas envoyé de pulsations au cours des 5 dernières heures.
Heartbeat
| summarize LastHeartbeat=max(TimeGenerated) by Computer
| where LastHeartbeat < ago(5h)
Availability rate (Taux de disponibilité)
Calculez le taux de disponibilité de chaque ordinateur connecté.
Heartbeat
// bin_at is used to set the time grain to 1 hour, starting exactly 24 hours ago
| summarize heartbeatPerHour = count() by bin_at(TimeGenerated, 1h, ago(24h)), Computer
| extend availablePerHour = iff(heartbeatPerHour > 0, true, false)
| summarize totalAvailableHours = countif(availablePerHour == true) by Computer
| extend availabilityRate = totalAvailableHours*100.0/24
Ne pas signaler de machines virtuelles
Les machines virtuelles qui n’ont pas signalé de pulsation au cours des 5 dernières minutes.
// To create an alert for this query, click '+ New alert rule'
Heartbeat
| where TimeGenerated > ago(24h)
| summarize LastCall = max(TimeGenerated) by Computer, _ResourceId
| where LastCall < ago(5m)
Liste des ordinateurs
Liste des ordinateurs avec Azure Update Management déployé.
Heartbeat
| where TimeGenerated>ago(12h) and OSType=="Linux" and notempty(Computer)
| summarize arg_max(TimeGenerated, Solutions, Computer, ResourceId, ComputerEnvironment, VMUUID) by SourceComputerId
| where Solutions has "updates"
| extend vmuuId=VMUUID, azureResourceId=ResourceId, osType=1, environment=iff(ComputerEnvironment=~"Azure", 1, 2), scopedToUpdatesSolution=true, lastUpdateAgentSeenTime=""
| join kind=leftouter
(
Update
| where TimeGenerated>ago(5h) and OSType=="Linux" and SourceComputerId in ((Heartbeat
| where TimeGenerated>ago(12h) and OSType=="Linux" and notempty(Computer)
| summarize arg_max(TimeGenerated, Solutions) by SourceComputerId
| where Solutions has "updates"
| distinct SourceComputerId))
| summarize hint.strategy=partitioned arg_max(TimeGenerated, UpdateState, Classification, Product, Computer, ComputerEnvironment) by SourceComputerId, Product, ProductArch
| summarize Computer=any(Computer), ComputerEnvironment=any(ComputerEnvironment), missingCriticalUpdatesCount=countif(Classification has "Critical" and UpdateState=~"Needed"), missingSecurityUpdatesCount=countif(Classification has "Security" and UpdateState=~"Needed"), missingOtherUpdatesCount=countif(Classification !has "Critical" and Classification !has "Security" and UpdateState=~"Needed"), lastAssessedTime=max(TimeGenerated), lastUpdateAgentSeenTime="" by SourceComputerId
| extend compliance=iff(missingCriticalUpdatesCount > 0 or missingSecurityUpdatesCount > 0, 2, 1)
| extend ComplianceOrder=iff(missingCriticalUpdatesCount > 0 or missingSecurityUpdatesCount > 0 or missingOtherUpdatesCount > 0, 1, 3)
)
on SourceComputerId
| project id=SourceComputerId, displayName=Computer, sourceComputerId=SourceComputerId, scopedToUpdatesSolution=true, missingCriticalUpdatesCount=coalesce(missingCriticalUpdatesCount, -1), missingSecurityUpdatesCount=coalesce(missingSecurityUpdatesCount, -1), missingOtherUpdatesCount=coalesce(missingOtherUpdatesCount, -1), compliance=coalesce(compliance, 4), lastAssessedTime, lastUpdateAgentSeenTime, osType=1, environment=iff(ComputerEnvironment=~"Azure", 1, 2), ComplianceOrder=coalesce(ComplianceOrder, 2)
| union(Heartbeat
| where TimeGenerated>ago(12h) and OSType=~"Windows" and notempty(Computer)
| summarize arg_max(TimeGenerated, Solutions, Computer, ResourceId, ComputerEnvironment, VMUUID) by SourceComputerId
| where Solutions has "updates"
| extend vmuuId=VMUUID, azureResourceId=ResourceId, osType=2, environment=iff(ComputerEnvironment=~"Azure", 1, 2), scopedToUpdatesSolution=true, lastUpdateAgentSeenTime=""
| join kind=leftouter
(
Update
| where TimeGenerated>ago(14h) and OSType!="Linux" and SourceComputerId in ((Heartbeat
| where TimeGenerated>ago(12h) and OSType=~"Windows" and notempty(Computer)
| summarize arg_max(TimeGenerated, Solutions) by SourceComputerId
| where Solutions has "updates"
| distinct SourceComputerId))
| summarize hint.strategy=partitioned arg_max(TimeGenerated, UpdateState, Classification, Title, Optional, Approved, Computer, ComputerEnvironment) by Computer, SourceComputerId, UpdateID
| summarize Computer=any(Computer), ComputerEnvironment=any(ComputerEnvironment), missingCriticalUpdatesCount=countif(Classification has "Critical" and UpdateState=~"Needed" and Approved!=false), missingSecurityUpdatesCount=countif(Classification has "Security" and UpdateState=~"Needed" and Approved!=false), missingOtherUpdatesCount=countif(Classification !has "Critical" and Classification !has "Security" and UpdateState=~"Needed" and Optional==false and Approved!=false), lastAssessedTime=max(TimeGenerated), lastUpdateAgentSeenTime="" by SourceComputerId
| extend compliance=iff(missingCriticalUpdatesCount > 0 or missingSecurityUpdatesCount > 0, 2, 1)
| extend ComplianceOrder=iff(missingCriticalUpdatesCount > 0 or missingSecurityUpdatesCount > 0 or missingOtherUpdatesCount > 0, 1, 3)
)
on SourceComputerId
| project id=SourceComputerId, displayName=Computer, sourceComputerId=SourceComputerId, scopedToUpdatesSolution=true, missingCriticalUpdatesCount=coalesce(missingCriticalUpdatesCount, -1), missingSecurityUpdatesCount=coalesce(missingSecurityUpdatesCount, -1), missingOtherUpdatesCount=coalesce(missingOtherUpdatesCount, -1), compliance=coalesce(compliance, 4), lastAssessedTime, lastUpdateAgentSeenTime, osType=2, environment=iff(ComputerEnvironment=~"Azure", 1, 2), ComplianceOrder=coalesce(ComplianceOrder, 2))
| order by ComplianceOrder asc, missingCriticalUpdatesCount desc, missingSecurityUpdatesCount desc, missingOtherUpdatesCount desc, displayName asc
| project-away ComplianceOrder
Rechercher dans la pulsation
Recherchez dans Pulsation pour rechercher une valeur spécifique dans la table Heartbeat./nNote que cette requête nécessite de mettre à jour le <paramètre SeachValue> pour produire des résultats
// This query requires a parameter to run. Enter value in SearchValue to find in table.
let SearchValue = "<SearchValue>";//Please update term you would like to find in the table.
Heartbeat
| where * contains tostring(SearchValue)
| take 1000