Uri.CheckSchemeName(String) Méthode

Définition

Détermine si le nom de schéma spécifié est valide.

public:
 static bool CheckSchemeName(System::String ^ schemeName);
public static bool CheckSchemeName (string schemeName);
public static bool CheckSchemeName (string? schemeName);
static member CheckSchemeName : string -> bool
Public Shared Function CheckSchemeName (schemeName As String) As Boolean

Paramètres

schemeName
String

Nom de schéma à valider.

Retours

Boolean

true si le nom du schéma est valide. Sinon, false.

Exemples

L’exemple suivant crée une Uri instance et vérifie si le nom du schéma est valide.

Uri^ address1 = gcnew Uri( "http://www.contoso.com/index.htm#search" );
Console::WriteLine( "address 1 {0} a valid scheme name",
   Uri::CheckSchemeName( address1->Scheme ) ? (String^)" has" : " does not have" );
if ( address1->Scheme == Uri::UriSchemeHttp )
{
   Console::WriteLine( "Uri is HTTP type" );
}

Console::WriteLine( address1->HostNameType );
Uri address1 = new Uri("http://www.contoso.com/index.htm#search");
Console.WriteLine("address 1 {0} a valid scheme name",
      Uri.CheckSchemeName(address1.Scheme) ? " has" : " does not have");

if (address1.Scheme == Uri.UriSchemeHttp)
    Console.WriteLine("Uri is HTTP type");

Console.WriteLine(address1.HostNameType);
let address1 = Uri "http://www.contoso.com/index.htm#search"
printfn $"""address 1 {if Uri.CheckSchemeName address1.Scheme then " has" else " does not have"} a valid scheme name"""

if address1.Scheme = Uri.UriSchemeHttp then
    printfn "Uri is HTTP type"

printfn $"{address1.HostNameType}"
Dim address1 As New Uri("http://www.contoso.com/index.htm#search")
Console.WriteLine("address 1 {0} a valid scheme name", IIf(Uri.CheckSchemeName(address1.Scheme), " has", " does not have")) 'TODO: For performance reasons this should be changed to nested IF statements

If address1.Scheme = Uri.UriSchemeHttp Then
    Console.WriteLine("Uri is HTTP type")
End If 
Console.WriteLine(address1.HostNameType)

Remarques

Cette méthode vérifie par défaut le nom du schéma en fonction de la norme RFC 2396. Si l’analyse IDN (International Resource Identifiers) ou Internationalized Domain Name (IDN) est activée, cette méthode vérifie le nom du schéma pour la validité selon RFC 3986. Le nom du schéma doit commencer par une lettre et doit contenir uniquement des lettres, des chiffres et les caractères « . », « + » ou « - ».

Pour plus d’informations sur la prise en charge de l’IRI, consultez la section Notes de la Uri classe.

S’applique à