SMS_CI_CurrentComplianceStatus Server WMI Class
Applies To: System Center Configuration Manager 2007, System Center Configuration Manager 2007 R2, System Center Configuration Manager 2007 R3, System Center Configuration Manager 2007 SP1, System Center Configuration Manager 2007 SP2
The SMS_CI_CurrentComplianceStatus Windows Management Instrumentation (WMI) class is an SMS Provider server class, in Configuration Manager, that represents the compliance status for a baseline configuration item.
Class SMS_CI_CurrentComplianceStatus : SMS_BaseClass
{
UInt32 CI_ID;
String CI_UniqueID;
UInt32 ComplianceState;
String ComplianceStateName;
String ComplianceStatusDetails;
UInt32 ComplianceValidationRuleFailures;
UInt32 DesiredState;
UInt32 EnforcementAction;
UInt32 EnforcementSource;
UInt32 EnforcementState;
String EnforcementStateName;
Boolean IsApplicable;
Boolean IsDetected;
UInt32 LastComplianceErrorID;
String LastComplianceMessageAssignment_UniqueID;
DateTime LastComplianceMessageTime;
UInt32 LastEnforcementErrorID;
String LastEnforcementMessageAssignment_UniqueID;
UInt32 LastEnforcementMessageID;
DateTime LastEnforcementMessageTime;
UInt32 MaxNoncomplianceCriticality;
UInt32 ResourceID;
UInt32 SDMPackageVersion;
};
Methods
The SMS_CI_CurrentComplianceStatus class does not define any methods.
Properties
CI_ID
Data type: UInt32Access type: Read
Qualifiers: [key]
The unique ID of the configuration item. This ID is unique only for the site.
CI_UniqueID
Data type: StringAccess type: Read
Qualifiers: [unique]
The unique ID of the configuration item. This ID is unique across sites.
ComplianceState
Data type: UInt32Access type: Read
Qualifiers: None
The compliance state for the configuration item.
ComplianceStateName
Data type: StringAccess type: Read
Qualifiers: None
The readable name of the compliance state. Possible values are:
0
Compliance State Unknown
1
Compliant
2
Non-Compliant
4
Error
ComplianceStatusDetails
Data type: StringAccess type: Read
Qualifiers: [lazy]
The noncompliance detail report sent by the client in XML format.
ComplianceValidationRuleFailures
Data type: UInt32Access type: Read
Qualifiers: None
The number of validation rule failures.
DesiredState
Data type: UInt32Access type: Read
Qualifiers: None
Desired compliance state of the configuration item on the computer.
EnforcementAction
Data type: UInt32Access type: Read
Qualifiers: None
The compliance enforcement action.
EnforcementSource
Data type: UInt32Access type: Read
Qualifiers: None
Source of the enforcement action. Possible values are:
0
NONE
1
Configuration Manager
2
USER
3
NAP
EnforcementState
Data type: UInt32Access type: Read
Qualifiers: None
The enforcement state. Possible values are:
0
Enforcement State Unknown
1
Enforcement started
2
Enforcement waiting for content
3
Waiting for another installation to complete
4
Waiting for maintenance window before installing
5
Restart required before installing
6
General failure
7
Pending installation
8
Installing update
9
Pending system restart
10
Successfully installed update
11
Failed to install update
12
Downloading update
13
Downloaded update
14
Failed to download update
EnforcementStateName
Data type: StringAccess type: Read
Qualifiers: None
The name of the enforcement state.
IsApplicable
Data type: BooleanAccess type: Read
Qualifiers: None
true if the configuration item is applicable on the computer.
IsDetected
Data type: BooleanAccess type: Read
Qualifiers: None
true if the configuration item is detected on the computer.
LastComplianceErrorID
Data type: UInt32Access type: Read
Qualifiers: None
The ID of the last compliance state error.
LastComplianceMessageAssignment_UniqueID
Data type: StringAccess type: Read
Qualifiers: None
The unique ID of the last compliance state message assignment.
LastComplianceMessageTime
Data type: DateTimeAccess type: Read
Qualifiers: None
Date and time of the last compliance state message.
LastEnforcementErrorID
Data type: UInt32Access type: Read
Qualifiers: None
The status message ID of the last enforcement failure.
LastEnforcementMessageAssignment_UniqueID
Data type: StringAccess type: Read
Qualifiers: None
The unique ID of the last enforcement state message assignment.
LastEnforcementMessageID
Data type: UInt32Access type: Read
Qualifiers: None
The ID of the last enforcement state message received.
LastEnforcementMessageTime
Data type: DateTimeAccess type: Read
Qualifiers: None
Date and time of the last enforcement state message.
MaxNoncomplianceCriticality
Data type: UInt32Access type: Read
Qualifiers: None
The maximum noncompliance severity reported by the client for the configuration item.
ResourceID
Data type: UInt32Access type: Read
Qualifiers: [key]
The unique ID of the resource for the configuration item.
SDMPackageVersion
Data type: UInt32Access type: Read
Qualifiers: None
System Definition Model (SDM) content version of the configuration item.
Remarks
Class qualifiers for this class include:
Read (read-only)
Secured
For more information about both the class qualifiers and the property qualifiers included in the Properties section, see Configuration Manager Class and Property Qualifiers.
Your application uses this class for compliance monitoring for a baseline configuration item.
Requirements
Runtime Requirements
For more information, see Configuration Manager Server Runtime Requirements.
Development Requirements
For more information, see Configuration Manager Server Development Requirements.