SMS_MeteredFiles Server WMI Class

Applies To: System Center Configuration Manager 2007, System Center Configuration Manager 2007 R2, System Center Configuration Manager 2007 R3, System Center Configuration Manager 2007 SP1, System Center Configuration Manager 2007 SP2

The SMS_MeteredFiles Windows Management Instrumentation (WMI) class is an SMS Provider server class, in Configuration Manager, that represents metered files and implements the matching between the meter rule and the file information.

The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties.

Class SMS_MeteredFiles : SMS_BaseClass
{
      Boolean ApplyToChildSites;
      String Comment;
      Boolean Enabled;
      String FileName;
      String FileVersion;
      UInt32 LanguageID;
      UInt32 MeteredFileID;
      String MeteredFileName;
      String MeteredFileVersion;
      UInt32 MeteredProductID;
      UInt32 MeteredProductLanguage;
      String OriginalFileName;
      String ProductName;
      UInt32 RuleID;
      String SecurityKey;
      String SiteCode;
      String SourceSite;
};

Methods

The SMS_MeteredFiles class does not define any methods.

Properties

  • ApplyToChildSites
    Data type: Boolean

    Access type : Read/Write

    Qualifiers: None

    true if the rule is applied to child sites.

  • Comment
    Data type: String

    Access type : Read/Write

    Qualifiers: None

    Optional comment about the rule.

  • Enabled
    Data type: Boolean

    Access type : Read/Write

    Qualifiers: None

    true if the rule is enabled.

  • FileName
    Data type: String

    Access type : Read/Write

    Qualifiers: None

    Name of the file. This property matches the file name specified in the metering rule.

  • FileVersion
    Data type: String

    Access type : Read/Write

    Qualifiers: None

    Version of the file. This property matches the version specified in the metering rule.

  • LanguageID
    Data type: UInt32

    Access type : Read/Write

    Qualifiers: None

    Locale of the file. This property matches the locale specified in the metering rule.

  • MeteredFileID
    Data type: UInt32

    Access type : Read/Write

    Qualifiers: [key]

    ID of the file that the rule meters. More information about this file can be found by matching this property value to the FileID value in the SMS_ProductFileInfo Server WMI Class class.

  • MeteredFileName
    Data type: String

    Access type : Read/Write

    Qualifiers: None

    The metered file name. This property value matches the FileName value or the OriginalFileName value, depending on which file matched the metered file.

  • MeteredFileVersion
    Data type: String

    Access type : Read/Write

    Qualifiers: None

    Version of the file that the rule meters.

  • MeteredProductID
    Data type: UInt32

    Access type : Read/Write

    Qualifiers: None

    ID of the product that the rule meters.

  • MeteredProductLanguage
    Data type: UInt32

    Access type : Read/Write

    Qualifiers: None

    Locale of the product for the file that was metered.

  • OriginalFileName
    Data type: String

    Access type : Read/Write

    Qualifiers: None

    Original file name to match as specified in the rule.

  • ProductName
    Data type: String

    Access type : Read/Write

    Qualifiers: None

    Name of the metering rule.

  • RuleID
    Data type: UInt32

    Access type : Read/Write

    Qualifiers: [key]

    ID of the rule.

  • SecurityKey
    Data type: String

    Access type : Read/Write

    Qualifiers: None

    Security key for the rule.

  • SiteCode
    Data type: String

    Access type : Read/Write

    Qualifiers: None

    Code of the site to which the rule is targeted.

  • SourceSite
    Data type: String

    Access type : Read/Write

    Qualifiers: None

    Code of the site that created the rule.

Remarks

There are no special class qualifiers for this class. For more information about both the class qualifiers and the property qualifiers included in the Properties section, see Configuration Manager Class and Property Qualifiers.

Software metering rules instruct the client agent to meter the running of certain applications. The data that the agent reports contains only information about the file that was metered, not the rules that caused it to be metered. This class is used to match the metering rules with metering data by combining information about each rule and its matching properties with files that the system knows about and the properties that were matched.

The matching done by this class works the same way as the matching on the client. Usage data reported in the summary classes can be matched to the metering rules by matching the FileID value in the summary data with the MeteredFileID value in this class. In a similar manner, software inventory can be matched to the rules that could meter the inventoried applications by matching the MeteredFileID value in this class to the FileID value in the SMS_G_System_SoftwareFile Server WMI Class class.

Requirements

Runtime Requirements

For more information, see Configuration Manager Server Runtime Requirements.

Development Requirements

For more information, see Configuration Manager Server Development Requirements.

See Also

Concepts

Software Metering Server WMI Classes
SMS_G_System_SoftwareFile Server WMI Class