OnlineTrustedServiceUserDomain.CertificationName property
The CertificationName property retrieves the common name of the Windows Live ID service.
This property is read-only.
Syntax
OnlineTrustedServiceUserDomain.CertificationName
Property value
This property returns a string value. The current value of the common name is "Windows Live ID".
Remarks
This property value is available only after the OnlineTrustedServiceUserDomain object has been enabled. For more information, see Enabled.
Examples
DIM config_manager
DIM admin_role
' *******************************************************************
' Create and initialize a ConfigurationManager object.
SUB InitObject()
CALL WScript.Echo( "Create ConfigurationManager object...")
SET config_manager = CreateObject _
("Microsoft.RightsManagementServices.Admin.ConfigurationManager")
CheckError()
CALL WScript.Echo( "Initialize...")
admin_role=config_manager.Initialize(false,"localhost",80,"","","")
CheckError()
END SUB
' *******************************************************************
' Retrieve Windows Live ID user domain information.
SUB GetLiveIdInfo()
DIM trustPolicy
DIM LiveIdDomain
' Retrieve the trust policy object.
SET trustPolicy = config_manager.Enterprise.TrustPolicy
CheckError()
' Retrieve the Windows Live ID user domain object.
SET LiveIdDomain = trustPolicy.OnlineTrustedServiceUserDomain
CheckError()
' Enable Windows Live ID user domains.
LiveIdDomain.Enabled = TRUE
CheckError()
IF IsNull(LiveIdDomain.Id) OR LEN(LiveIdDomain.Id) = 0 THEN
CALL RaiseError(-601, "Enable Live ID user domain failed.")
END IF
CALL WScript.Echo("OnlineTrustedServiceUserDomain.Enabled: Id = " _
& LiveIdDomain.Id _
& " Certification Name = " _
& LiveIdDomain.CertificationName _
& " Certificate Expiration = " _
& LiveIdDomain.CertificateExpirationTime)
' Add excluded users to the domain.
LiveIdDomain.ExcludedUsers.Clear()
LiveIdDomain.ExcludedUsers.Add("LiveId1@example.com")
LiveIdDomain.ExcludedUsers.Add("LiveId2@example.com")
LiveIdDomain.ExcludedUsers.Update()
CheckError()
CALL WScript.Echo("LiveIdUserDomain: excluded count=" & _
LiveIdDomain.ExcludedUsers.Count)
END SUB
' *******************************************************************
' Error checking function.
FUNCTION CheckError()
CheckError = Err.number
IF Err.number <> 0 THEN
CALL WScript.Echo( vbTab & "*****Error Number: " _
& Err.number _
& " Desc:" _
& Err.Description _
& "*****")
WScript.StdErr.Write(Err.Description)
WScript.Quit( Err.number )
END IF
END FUNCTION
' *******************************************************************
' Generate a runtime error.
SUB RaiseError(errId, desc)
CALL Err.Raise( errId, "", desc )
CheckError()
END SUB
Requirements
Minimum supported client |
None supported |
Minimum supported server |
Windows Server 2008 |
Assembly |
|