BinHexEncoder.Convert Method (Byte[], Int32, Int32, Byte[], Int32, Int32, Boolean, out Int32, out Int32, out Boolean)
The Convert method applies BinHex encoding.
Namespace: Microsoft.Exchange.Data.Mime.Encoders
Assembly: Microsoft.Exchange.Data.Common (in microsoft.exchange.data.common.dll)
Syntax
'Declaration
Public Overrides NotOverridable Sub Convert ( _
input As Byte(), _
inputIndex As Integer, _
inputSize As Integer, _
output As Byte(), _
outputIndex As Integer, _
outputSize As Integer, _
flush As Boolean, _
<OutAttribute> ByRef inputUsed As Integer, _
<OutAttribute> ByRef outputUsed As Integer, _
<OutAttribute> ByRef completed As Boolean _
)
public override sealed void Convert (
byte[] input,
int inputIndex,
int inputSize,
byte[] output,
int outputIndex,
int outputSize,
bool flush,
out int inputUsed,
out int outputUsed,
out bool completed
)
public:
virtual void Convert (
array<unsigned char>^ input,
int inputIndex,
int inputSize,
array<unsigned char>^ output,
int outputIndex,
int outputSize,
bool flush,
[OutAttribute] int% inputUsed,
[OutAttribute] int% outputUsed,
[OutAttribute] bool% completed
) override sealed
public final void Convert (
byte[] input,
int inputIndex,
int inputSize,
byte[] output,
int outputIndex,
int outputSize,
boolean flush,
/** @attribute OutAttribute() */ /** @ref */ int inputUsed,
/** @attribute OutAttribute() */ /** @ref */ int outputUsed,
/** @attribute OutAttribute() */ /** @ref */ boolean completed
)
JScript does not support passing value-type arguments by reference.
Parameters
- input
A byte array that contains the data to encode.
- inputIndex
The zero-based byte offset in input at which to begin reading the data to encode.
- inputSize
The maximum number of bytes to be read from input.
- output
A byte array that will contain the BinHex-encoded data.
- outputIndex
The zero-based byte offset in output at which to begin writing the data to convert.
- outputSize
The number of bytes to use in output.
- flush
Set flush to true if this is the last block of data to be encoded. Otherwise, set flush to false.
- inputUsed
The number of bytes that are actually read from input.
- outputUsed
The number of bytes that are actually written to output.
- completed
A Boolean value that indicates that all data has been successfully encoded. The completed parameter is set to true when either all of input is consumed but the data is not flushed, or the rest of input was flushed.
Exceptions
Exception type | Condition |
---|---|
ArgumentOutOfRangeException | This exception is thrown if any one of the following is true:
|
ArgumentNullException | This exception is thrown if either input is null (Nothing in Visual Basic) and inputSize is nonzero or output is null (Nothing in Visual Basic). |
Thread Safety
Any public static (Shared in Visual Basic) members of this type are thread safe. Any instance members are not guaranteed to be thread safe.
Platforms
Development Platforms
Windows XP Professional with Service Pack 2 (SP2), Windows Server 2003,
Target Platforms
Windows Server 2003