NdisMRegisterAdapterShutdownHandler (Windows CE 5.0)
This function registers a NIC-driver-supplied MiniportShutdown function to be called when the system is shutting down.
VOID NdisMRegisterAdapterShutdownHandler(NDIS_HANDLE MiniportHandle,PVOID ShutdownContext,ADAPTER_SHUTDOWN_HANDLER ShutdownHandler);
Parameters
- MiniportHandle
[in] Specifies the handle input to the MiniportInitialize function. - ShutdownContext
[in] Pointer to a driver-determined context area. This pointer is passed to the function at ShutdownHandler when it is called. - ShutdownHandler
[in] Specifies the entry point of the caller's MiniportShutdown function.
Return Values
None.
Remarks
Any version of this function prior to Windows CE .NET 4.0 is a stub that does not work.
Requirements
OS Versions: Windows CE .NET 4.0 and later.
Header: Ndis.h.
Link Library: Ndis.dll.
See Also
MiniportInitialize | MiniportShutdown