WMI Reference
Microsoft Office Communications Server 2007 and Microsoft Office Communications Server 2007 R2 will reach end of support on January 9, 2018. To stay supported, you will need to upgrade. For more information, see Resources to help you upgrade your Office 2007 servers and clients.
The following table lists the various configuration settings that can be set through WMI for the \\cimv2\MSFT_SIPQMSExternalConsumer singleton class. This class already exists, so you will not need to create it.
Table 2. WMI Settings for Class MSFT_ SIPQMSExternalConsumer
Property Name | Description | Type | Default | Range | Access Type |
---|---|---|---|---|---|
InstanceID |
Class identifier |
GUID |
53094317-4455-44ed-B8D5-A716972B3344 |
Up to 1024 characters |
Read Only |
ConsumerURL |
The URL that A/V Metric Reports will be posted too. Note The host name in the URL must be identical to Subject field of the server certificate. For instance, if the server certificate is configured as contoso.voip-client1.com, the consumer URL must be https://contoso.voip-client1.com. |
String |
NULL |
Valid HTTPS or HTTP URL |
Read/Write |
ConsumerName |
A display name for the consumer. |
String |
NULL |
Up to 256 characters |
Read/Write |
ClientCertIssuer |
A binary array in raw data format that represents the certification authority that issued the certificate. This data is in ASN.1 byte array format. This setting is used only if ConsumerURL is an HTTPS URL. This setting should be NULL if the client will not use a certificate. |
uint8 |
NULL |
N/A |
Read/Write |
ClientCertSN |
A binary array in raw data format that represents the serial number of the client certificate.* This setting is used only if ConsumerURL is an HTTPS URL. This setting should be NULL if the client will not use a certificate. |
uint8 |
NULL |
N/A |
Read/Write |
Enabled |
If True, the QoE Monitoring Server will send A/V Metric Reports to the configured consumer. |
Boolean |
False |
N/A |
Read/Write |
ErrorRetryEnabled |
If True, the QoE Monitoring Server will retry when transient errors occur. |
Boolean |
True |
N/A |
Read/Write |
MaxPostBatchSize |
Maximum number of reports to send in one transaction. |
uint32 |
50 |
5-100 |
Read/Write |
MaxQueueSize |
The maximum amount of memory (in KB) that is used to cache metric reports on behalf of the consumer. If the queue limit is exceeded, the QoE Monitoring Server will discard the oldest reports first. If MaxQueueSize is set to 0, the buffer size has no upper limit. Because individual reports may range from 2 KB to 8 KB, we recommend against setting MaxQueueSize to less than 10. |
uint32 |
50,000 |
0-MAX_INT |
Read/Write |
* The certificate serial number can be viewed from the Certificates snap-in. The binary array should be stored here in reverse order to the order that is shown by the Certificates snap-in. WMI will show the array values in decimal, but the Certificates snap-in displays the values in hexadecimal.