Timer.Interval Eigenschaft

Definition

Ruft das Intervall in Millisekunden ab, in dem das Elapsed-Ereignis ausgelöst wird, oder legt dieses fest.

public:
 property double Interval { double get(); void set(double value); };
public double Interval { get; set; }
[System.Timers.TimersDescription("TimerInterval")]
public double Interval { get; set; }
[System.Timers.TimersDescription("TimerInterval")]
[System.ComponentModel.SettingsBindable(true)]
public double Interval { get; set; }
member this.Interval : double with get, set
[<System.Timers.TimersDescription("TimerInterval")>]
member this.Interval : double with get, set
[<System.Timers.TimersDescription("TimerInterval")>]
[<System.ComponentModel.SettingsBindable(true)>]
member this.Interval : double with get, set
Public Property Interval As Double

Eigenschaftswert

Die Zeit zwischen den Elapsed-Ereignissen in Millisekunden. Der Wert muss größer als 0 (null) und kleiner oder gleich Int32.MaxValue sein. Der Standardwert ist 100 Millisekunden.

Attribute

Ausnahmen

Das Intervall ist kleiner oder gleich 0 (null).

- oder -

Das Intervall ist größer als Int32.MaxValue, und der Timer ist derzeit aktiviert. (Wenn der Zeitgeber nicht gerade aktiviert ist, wird keine Ausnahme ausgelöst, bis er aktiviert wird.)

Beispiele

Das folgende Beispiel instanziiert ein Timer-Objekt, das sein Timer.Elapsed-Ereignis alle zwei Sekunden (2000 Millisekunden) auslöst, einen Ereignishandler für das Ereignis einrichtet und den Timer startet. Der Ereignishandler zeigt den Wert der ElapsedEventArgs.SignalTime-Eigenschaft bei jedem Auslösen an.

using namespace System;
using namespace System::Timers;

public ref class Example
{
private:
    static System::Timers::Timer^ aTimer;

public:
    static void Demo()
    {
        // Create a timer and set a two second interval.
        aTimer = gcnew System::Timers::Timer();
        aTimer->Interval = 2000;

        // Hook up the Elapsed event for the timer. 
        aTimer->Elapsed += gcnew System::Timers::ElapsedEventHandler(Example::OnTimedEvent);

        // Have the timer fire repeated events (true is the default)
        aTimer->AutoReset = true;

        // Start the timer
        aTimer->Enabled = true;

        Console::WriteLine("Press the Enter key to exit the program at any time... ");
        Console::ReadLine();
    }

private:
    static void OnTimedEvent(Object^ source, System::Timers::ElapsedEventArgs^ e)
    {
        Console::WriteLine("The Elapsed event was raised at {0}", e->SignalTime);
    }
};

int main()
{
    Example::Demo();
}
// The example displays output like the following: 
//       Press the Enter key to exit the program at any time... 
//       The Elapsed event was raised at 5/20/2015 8:48:58 PM 
//       The Elapsed event was raised at 5/20/2015 8:49:00 PM 
//       The Elapsed event was raised at 5/20/2015 8:49:02 PM 
//       The Elapsed event was raised at 5/20/2015 8:49:04 PM 
//       The Elapsed event was raised at 5/20/2015 8:49:06 PM
using System;
using System.Timers;

public class Example
{
    private static Timer aTimer;

    public static void Main()
    {
        // Create a timer and set a two second interval.
        aTimer = new System.Timers.Timer();
        aTimer.Interval = 2000;

        // Hook up the Elapsed event for the timer. 
        aTimer.Elapsed += OnTimedEvent;

        // Have the timer fire repeated events (true is the default)
        aTimer.AutoReset = true;

        // Start the timer
        aTimer.Enabled = true;

        Console.WriteLine("Press the Enter key to exit the program at any time... ");
        Console.ReadLine();
    }

    private static void OnTimedEvent(Object source, System.Timers.ElapsedEventArgs e)
    {
        Console.WriteLine("The Elapsed event was raised at {0}", e.SignalTime);
    }
}
// The example displays output like the following: 
//       Press the Enter key to exit the program at any time... 
//       The Elapsed event was raised at 5/20/2015 8:48:58 PM 
//       The Elapsed event was raised at 5/20/2015 8:49:00 PM 
//       The Elapsed event was raised at 5/20/2015 8:49:02 PM 
//       The Elapsed event was raised at 5/20/2015 8:49:04 PM 
//       The Elapsed event was raised at 5/20/2015 8:49:06 PM
open System.Timers

let onTimedEvent source (e: ElapsedEventArgs) =
    printfn $"The Elapsed event was raised at {e.SignalTime}"

// Create a timer and set a two second interval.
let aTimer = new Timer()
aTimer.Interval <- 2000

// Hook up the Elapsed event for the timer. 
aTimer.Elapsed.AddHandler onTimedEvent

// Have the timer fire repeated events (true is the default)
aTimer.AutoReset <- true

// Start the timer
aTimer.Enabled <- true

printfn "Press the Enter key to exit the program at any time... "
stdin.ReadLine() |> ignore

// The example displays output like the following: 
//       Press the Enter key to exit the program at any time... 
//       The Elapsed event was raised at 5/20/2015 8:48:58 PM 
//       The Elapsed event was raised at 5/20/2015 8:49:00 PM 
//       The Elapsed event was raised at 5/20/2015 8:49:02 PM 
//       The Elapsed event was raised at 5/20/2015 8:49:04 PM 
//       The Elapsed event was raised at 5/20/2015 8:49:06 PM
Imports System.Timers

Public Module Example
    Private aTimer As Timer

    Public Sub Main()
        ' Create a timer and set a two second interval.
        aTimer = New System.Timers.Timer()
        aTimer.Interval = 2000

        ' Hook up the Elapsed event for the timer.  
        AddHandler aTimer.Elapsed, AddressOf OnTimedEvent

        ' Have the timer fire repeated events (true is the default)
        aTimer.AutoReset = True

        ' Start the timer
        aTimer.Enabled = True

        Console.WriteLine("Press the Enter key to exit the program at any time... ")
        Console.ReadLine()
    End Sub

    Private Sub OnTimedEvent(source As Object, e As System.Timers.ElapsedEventArgs)
        Console.WriteLine("The Elapsed event was raised at {0}", e.SignalTime)
    End Sub
End Module
' The example displays output like the following: 
'       Press the Enter key to exit the program at any time... 
'       The Elapsed event was raised at 5/20/2015 8:48:58 PM 
'       The Elapsed event was raised at 5/20/2015 8:49:00 PM 
'       The Elapsed event was raised at 5/20/2015 8:49:02 PM 
'       The Elapsed event was raised at 5/20/2015 8:49:04 PM 
'       The Elapsed event was raised at 5/20/2015 8:49:06 PM

Hinweise

Sie verwenden die Interval -Eigenschaft, um die Häufigkeit zu bestimmen, mit der das Elapsed Ereignis ausgelöst wird. Da die Timer -Klasse von der Systemuhr abhängt, hat sie dieselbe Auflösung wie die Systemuhr. Das bedeutet, dass das Elapsed-Ereignis in einem durch die Auflösung der Systemuhr definierten Intervall ausgelöst wird, wenn die Interval-Eigenschaft kleiner als die Systemuhrauflösung ist. Im folgenden Beispiel wird die Interval -Eigenschaft auf 5 Millisekunden festgelegt. Bei Ausführung auf einem Windows-System, dessen Systemuhr eine Auflösung von ungefähr 15 Millisekunden aufweist, löst das Ereignis ungefähr alle 15 Millisekunden und nicht alle 5 Millisekunden aus.

Hinweis

Die verwendete Systemuhr ist die gleiche Uhr, die von GetTickCount verwendet wird, die nicht von Änderungen betroffen ist, die mit timeBeginPeriod und timeEndPeriod vorgenommen wurden.

using System;
using System.IO;
using System.Collections.Generic;
using System.Timers;

public class Example
{
   private static Timer aTimer;
   private static List<String> eventlog;
   private static int nEventsFired = 0;
   private static DateTime previousTime;
       
   public static void Main()
   {
        eventlog = new List<String>();
        
        StreamWriter sr = new StreamWriter(@".\Interval.txt");
        // Create a timer with a five millisecond interval.
        aTimer = new Timer(5);
        aTimer.Elapsed += OnTimedEvent;
        // Hook up the Elapsed event for the timer. 
        aTimer.AutoReset = true;
        sr.WriteLine("The timer should fire every {0} milliseconds.", 
                     aTimer.Interval);
        aTimer.Enabled = true;

        Console.WriteLine("Press the Enter key to exit the program... ");
        Console.ReadLine();
        foreach (var item in eventlog)
           sr.WriteLine(item);
        sr.Close();
        Console.WriteLine("Terminating the application...");
   }

    private static void OnTimedEvent(Object source, ElapsedEventArgs e)
    {
        eventlog.Add(String.Format("Elapsed event at {0:HH':'mm':'ss.ffffff} ({1})", 
                                   e.SignalTime, 
                                   nEventsFired++ == 0 ? 
                                      0.0 : (e.SignalTime - previousTime).TotalMilliseconds));
        previousTime = e.SignalTime;
        if (nEventsFired == 20) {
           Console.WriteLine("No more events will fire...");
           aTimer.Enabled = false;
        }
    }
}
// The example writes output like the following to a file:
//       The timer should fire every 5 milliseconds.
//       Elapsed event at 08:42:49.370344 (0)
//       Elapsed event at 08:42:49.385345 (15.0015)
//       Elapsed event at 08:42:49.400347 (15.0015)
//       Elapsed event at 08:42:49.415348 (15.0015)
//       Elapsed event at 08:42:49.430350 (15.0015)
//       Elapsed event at 08:42:49.445351 (15.0015)
//       Elapsed event at 08:42:49.465353 (20.002)
//       Elapsed event at 08:42:49.480355 (15.0015)
//       Elapsed event at 08:42:49.495356 (15.0015)
//       Elapsed event at 08:42:49.510358 (15.0015)
//       Elapsed event at 08:42:49.525359 (15.0015)
//       Elapsed event at 08:42:49.540361 (15.0015)
//       Elapsed event at 08:42:49.555362 (15.0015)
//       Elapsed event at 08:42:49.570364 (15.0015)
//       Elapsed event at 08:42:49.585365 (15.0015)
//       Elapsed event at 08:42:49.605367 (20.002)
//       Elapsed event at 08:42:49.620369 (15.0015)
//       Elapsed event at 08:42:49.635370 (15.0015)
//       Elapsed event at 08:42:49.650372 (15.0015)
//       Elapsed event at 08:42:49.665373 (15.0015)
open System
open System.IO
open System.Timers

let aTimer = new Timer 5
let eventlog = ResizeArray()
let mutable nEventsFired = 0
let mutable previousTime = DateTime()
       
let onTimedEvent source (e: ElapsedEventArgs) =
    String.Format("Elapsed event at {0:HH':'mm':'ss.ffffff} ({1})", e.SignalTime, if nEventsFired = 0 then 0. else (e.SignalTime - previousTime).TotalMilliseconds)
    |> eventlog.Add
    nEventsFired <- nEventsFired + 1

    previousTime <- e.SignalTime

    if nEventsFired = 20 then
        printfn "No more events will fire..."
        aTimer.Enabled <- false

[<EntryPoint>]
let main _ =
    use sr = new StreamWriter(@".\Interval.txt")
    // Create a timer with a five millisecond interval.
    aTimer.Elapsed.AddHandler onTimedEvent
    // Hook up the Elapsed event for the timer. 
    aTimer.AutoReset <- true
    sr.WriteLine $"The timer should fire every {aTimer.Interval} milliseconds."
    aTimer.Enabled <- true

    printfn "Press the Enter key to exit the program... "
    stdin.ReadLine() |> ignore
    for item in eventlog do
        sr.WriteLine item
    printfn "Terminating the application..."
    0

// The example writes output like the following to a file:
//       The timer should fire every 5 milliseconds.
//       Elapsed event at 08:42:49.370344 (0)
//       Elapsed event at 08:42:49.385345 (15.0015)
//       Elapsed event at 08:42:49.400347 (15.0015)
//       Elapsed event at 08:42:49.415348 (15.0015)
//       Elapsed event at 08:42:49.430350 (15.0015)
//       Elapsed event at 08:42:49.445351 (15.0015)
//       Elapsed event at 08:42:49.465353 (20.002)
//       Elapsed event at 08:42:49.480355 (15.0015)
//       Elapsed event at 08:42:49.495356 (15.0015)
//       Elapsed event at 08:42:49.510358 (15.0015)
//       Elapsed event at 08:42:49.525359 (15.0015)
//       Elapsed event at 08:42:49.540361 (15.0015)
//       Elapsed event at 08:42:49.555362 (15.0015)
//       Elapsed event at 08:42:49.570364 (15.0015)
//       Elapsed event at 08:42:49.585365 (15.0015)
//       Elapsed event at 08:42:49.605367 (20.002)
//       Elapsed event at 08:42:49.620369 (15.0015)
//       Elapsed event at 08:42:49.635370 (15.0015)
//       Elapsed event at 08:42:49.650372 (15.0015)
//       Elapsed event at 08:42:49.665373 (15.0015)
Imports System.Collections.Generic
Imports System.IO
Imports System.Timers

Module Example
   Private WithEvents aTimer As Timer
   Private eventlog As List(Of String)
   Private nEventsFired As Integer = 0
   Private previousTime As Date

   Public Sub Main()
        eventlog = New List(Of String)()
        
        Dim sr As New StreamWriter(".\Interval.txt")
        ' Create a timer with a five millisecond interval.
        aTimer = New Timer(5)
        aTimer.AutoReset = True
        sr.WriteLine("The timer should fire every {0} milliseconds.", 
                     aTimer.Interval)
        aTimer.Enabled = True

        
        Console.WriteLine("Press the Enter key to exit the program... ")
        Console.ReadLine()
        For Each item In eventlog
           sr.WriteLine(item)
        Next
        sr.Close()
        Console.WriteLine("Terminating the application...")
   End Sub

    Private Sub OnTimedEvent(source As Object, e As ElapsedEventArgs) _
                             Handles aTimer.Elapsed
        eventlog.Add(String.Format("Elapsed event at {0:HH':'mm':'ss.ffffff} ({1})", 
                                   e.SignalTime, 
                                   If(nEventsFired = 0, 
                                      0.0, (e.SignalTime - previousTime).TotalMilliseconds)))
        nEventsFired += 1
        previousTime = e.SignalTime
        if nEventsFired = 20 Then
           Console.WriteLine("No more events will fire...")
           aTimer.Enabled = False
        End If
   End Sub
End Module
' The example displays the following output:
'       The timer should fire every 5 milliseconds.
'       Elapsed event at 08:42:49.370344 (0)
'       Elapsed event at 08:42:49.385345 (15.0015)
'       Elapsed event at 08:42:49.400347 (15.0015)
'       Elapsed event at 08:42:49.415348 (15.0015)
'       Elapsed event at 08:42:49.430350 (15.0015)
'       Elapsed event at 08:42:49.445351 (15.0015)
'       Elapsed event at 08:42:49.465353 (20.002)
'       Elapsed event at 08:42:49.480355 (15.0015)
'       Elapsed event at 08:42:49.495356 (15.0015)
'       Elapsed event at 08:42:49.510358 (15.0015)
'       Elapsed event at 08:42:49.525359 (15.0015)
'       Elapsed event at 08:42:49.540361 (15.0015)
'       Elapsed event at 08:42:49.555362 (15.0015)
'       Elapsed event at 08:42:49.570364 (15.0015)
'       Elapsed event at 08:42:49.585365 (15.0015)
'       Elapsed event at 08:42:49.605367 (20.002)
'       Elapsed event at 08:42:49.620369 (15.0015)
'       Elapsed event at 08:42:49.635370 (15.0015)
'       Elapsed event at 08:42:49.650372 (15.0015)
'       Elapsed event at 08:42:49.665373 (15.0015)

Wenn Ihre App eine höhere Auflösung als die Timer der Klasse oder der Systemuhr erfordert, verwenden Sie die hochauflösenden Multimediatimer. Weitere Informationen finden Sie unter Vorgehensweise: Verwenden des High-Resolution Timer.

Wenn das Intervall nach dem Starten von Timer festgelegt wird, wird die Anzahl zurückgesetzt. Wenn Sie beispielsweise das Intervall auf 5 Sekunden und dann die Enabled -Eigenschaft auf truefestlegen, beginnt die Anzahl zu dem Zeitpunkt Enabled , zu dem festgelegt wird. Wenn Sie das Intervall auf 10 Sekunden zurücksetzen, wenn die Anzahl 3 Sekunden beträgt, wird das Elapsed Ereignis zum ersten Mal ausgelöst, nachdem Enabled auf truefestgelegt wurde.

Wenn Enabled auf true festgelegt ist und AutoReset auf falsefestgelegt ist, löst das TimerElapsed -Ereignis nur einmal aus, wenn das Intervall zum ersten Mal verstrichen ist. Enabled wird dann auf falsefestgelegt.

Hinweis

Wenn Enabled und AutoReset auf falsefestgelegt sind und der Timer zuvor aktiviert wurde, bewirkt das Festlegen der Interval -Eigenschaft, dass das Elapsed Ereignis einmal ausgelöst wird, als ob die Enabled Eigenschaft auf truefestgelegt wäre. Wenn Sie das Intervall ohne Auslösen des Ereignisses festlegen möchten, können Sie die Enabled -Eigenschaft vorübergehend auf truefestlegen, die Interval -Eigenschaft auf das gewünschte Zeitintervall festlegen und die -Eigenschaft dann sofort wieder auf falsefestlegenEnabled.

Gilt für:

Weitere Informationen